Seed-hawk GRANULAR AND LIQUID TANKS 2010 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel de jardinage Seed-hawk GRANULAR AND LIQUID TANKS 2010. Seed Hawk GRANULAR AND LIQUID TANKS 2010 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 72
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
2010 Manual Retail Price $40.00 CDN/US
Version 2.1
Vue de la page 0
1 2 3 4 5 6 ... 71 72

Résumé du contenu

Page 1

2010 Manual Retail Price $40.00 CDN/US Version 2.1

Page 2

Seed Hawk Manual Granular and Liquid Tanks Page 8 2.3 GENERAL SAFETY PRACTICES  Read and understand the contents of this Operator’s Manual prio

Page 3 - Table of Contents

Seed Hawk Manual Granular and Liquid Tanks Page 9 2.4 MAINTENANCE SAFETY  Read and understand all information provided in this Operator’s Manua

Page 4

Seed Hawk Manual Granular and Liquid Tanks Page 10 2.5 HYDRAULIC SAFETY  Ensure that all hydraulic system components are kept clean and in prop

Page 5 - 1.0 INTRODUCTION

Seed Hawk Manual Granular and Liquid Tanks Page 11 2.6 TRANSPORT SAFETY  Ensure that drill or tank is attached to tractor properly.  Ensure

Page 6

Seed Hawk Manual Granular and Liquid Tanks Page 12 2.9 SAFETY SIGNS Location of Safety Sign on Implement FIG. 3

Page 7

Seed Hawk Manual Granular and Liquid Tanks Page 13 2.9.1 Applied Safety Signs CAUTION! Read Operator’s Manual before operating machine. Read

Page 8 - CAUTIONCAUTION

Seed Hawk Manual Granular and Liquid Tanks Page 14 DANGER! ENTANGLEMENT HAZARD. Keep hands, feet, and clothing awa

Page 9 - 2.2.1 Key Safety Reminders:

Seed Hawk Manual Granular and Liquid Tanks Page 15 Safety Signs on Replacement Parts Ensure that parts or components that are replaced on the imp

Page 10 - 2.3 GENERAL SAFETY PRACTICES

3.0 SPECIFICATIONS Seed Hawk Manual Granular and Liquid Tanks Page 16 3.1 HARDWARE TORQUE 3.1.1 SAE Bolt Diameter Bol

Page 11 - 2.4 MAINTENANCE SAFETY

Seed Hawk Manual Granular and Liquid Tanks Page 17 3.2 TIRE PRESSURE Use the following chart to check and adjust, if necessary, tire pressure.

Page 13 - 2.8 TIRE SAFETY

3.0 OPERATION Seed Hawk Manual Granular and Liquid Tanks Page 18 4.1 FILL AUGER - 10 inch FIG 1 DANGER! ELECTROCUTION HAZARD. Use extreme caution

Page 14 - 2.9 SAFETY SIGNS

Seed Hawk Manual Granular and Liquid Tanks Page 19 4.1.1 Positioning the Auger NOTE: Ensure that the area in the vicinity of auger operation is f

Page 15 - 2.9.1 Applied Safety Signs

Seed Hawk Manual Granular and Liquid Tanks Page 20 1. Ensure that all screens and shrouds are in place and that cleanout gate on each meter, FIG.

Page 16

Seed Hawk Manual Granular and Liquid Tanks Page 21 4.1.4 Auger Transport Position IMPORTANT: Fill auger should always be secured for transport

Page 17

Seed Hawk Manual Granular and Liquid Tanks Page 22 4.2 FAN(S) (OPTIONAL) (3/4” NON COLOR CODED) Connect the pair of 3/4” hydraulic lines to supp

Page 18 - 3.0 SPECIFICATIONS

Seed Hawk Manual Granular and Liquid Tanks Page 23 4.4 METERING ROLLER The metering roller provided in each compartment is designed to accommodat

Page 19 - 3.2 TIRE PRESSURE

Seed Hawk Manual Granular and Liquid Tanks Page 24 4.5 SEEDHAWK PRESSURIZED METERING SYSTEM FAN(S) Some models are configures

Page 20 - 3.0 OPERATION

Seed Hawk Manual Granular and Liquid Tanks Page 25 4.6 CHECKING AIR AND PRODUCT FLOW The test procedure outlined below serves as a guideline for

Page 21 - 4.1.2 Operating the Auger

Seed Hawk Manual Granular and Liquid Tanks Page 26 4.7 GROUND DRIVE METERING The ground drive metering system is engaged by activating an electr

Page 22

5.0 LIQUID SYSTEM OPERATION Seed Hawk Manual Granular and Liquid Tanks Page 27 5.1 SEED HAWK LIQUID FERTILIZER SYSTEM FIG. 39. 1 Tank 2 Fill cap

Page 23

Table of Contents 1.0 Introduction 3-5 1.1 Description of the Machine 4 1.2 Illustration of the Machine 4 1.3 Serial Number

Page 24

Seed Hawk Manual Granular and Liquid Tanks Page 28 5.2 SYSTEM FLOW DESCRIPTION The metering pump, ground driven by the metering wheel, draws liqu

Page 25 - 4.4 METERING ROLLER

Seed Hawk Manual Granular and Liquid Tanks Page 29 5.3 FILLING THE LIQUID FERTILIZER TANK To fill the liquid fertilizer tank: 1. Remove fill ca

Page 26

Seed Hawk Manual Granular and Liquid Tanks Page 30 5.5 CHECKING FERTILIZER RUNS Perform the following test to ensure that each fertilizer run is

Page 27

Seed Hawk Manual Granular and Liquid Tanks Page 31 5.7 AGITATE LIQUID FERTILIZER It is recommended that the contents in the liquid fertilizer tan

Page 28 - 4.7 GROUND DRIVE METERING

Seed Hawk Manual Granular and Liquid Tanks Page 32 A liquid fill pump is an option when the liquid onboard tank is ordered. Usually located at t

Page 29 - 5.0 LIQUID SYSTEM OPERATION

Seed Hawk Manual Granular and Liquid Tanks Page 33 FIG.18 5.8 LIQUID FERTILIZER APPLICATION RATES JOHN BLUE PUMP Perform the following steps to

Page 30 - 5.2 SYSTEM FLOW DESCRIPTION

Seed Hawk Manual Granular and Liquid Tanks Page 34 5.8.1 Pump Settings 30.5L32 Rear Axle 3

Page 31

Seed Hawk Manual Granular and Liquid Tanks Page 35 5.9 LIQUID PUMP GEAR RATIOS Gearing for Pumps Driven from the Rear Axle 30.5L32 Axle LM-4450

Page 32 - 5.5 CHECKING FERTILIZER RUNS

Seed Hawk Manual Granular and Liquid Tanks Page 36 Variable rate liquid chart. NOTE: Above charts are f

Page 33

7.0 INTRODUCTION Seed Hawk Manual Seed Hawk Air Drill Monitor II Page 37 The SEED HAWK Air Drill Monitor is capable of monitoring and displaying:

Page 34

6.0 Maintenance 36 6.1 Maintenance Schedule 36 7.0 Air Drill Monitor Introduction 37 8.0 Operation 38-46 8.1 Normal Startu

Page 35

8.0 OPERATION Seed Hawk Manual Seed Hawk Air Drill Monitor II Page 38 8.1 NORMAL STARTUP Once all sensors have been installed and power has been pr

Page 36 - 5.8.1 Pump Settings

Seed Hawk Manual Granular and Liquid Tanks Page 39 8.3 CHANGING DISPLAYED FUNCTIONS The display of the monitor can be changed to show any of the

Page 37 - 5.9 LIQUID PUMP GEAR RATIOS

Seed Hawk Manual Granular and Liquid Tanks Page 40 In this example the top display is changed from reading Field Area to Fan RPM. Having pressed t

Page 38 - 6.0 MAINTENANCE

Seed Hawk Manual Granular and Liquid Tanks Page 41 8.5 ALARMS The alarm display will become active when any conditions fall below or rise above t

Page 39 - 7.0 INTRODUCTION

Seed Hawk Manual Granular and Liquid Tanks Page 42 8.5.3 Low and High Fan Speed Alarm A Low or High Fan Speed alarm occurs when fan RPM’s exceed

Page 40 - 8.0 OPERATION

Seed Hawk Manual Granular and Liquid Tanks Page 43 8.6 SPECIAL START-UP A special start-up screen will appear when the monitor is turned on in

Page 41 - 8.4 CHANGING DISPLAY SIZE

Seed Hawk Manual Granular and Liquid Tanks Page 44 8.6.1 Learn New System The Learn New System mode is a onetime process that identifies each se

Page 42

Seed Hawk Manual Granular and Liquid Tanks Page 45 5. Install New System- Plug your sensors in as the monitor asks for them. For sensors that are

Page 43 - 8.5.2 Empty Bin

Seed Hawk Manual Granular and Liquid Tanks Page 46 6. When all sensors have been installed or skipped the monitor will display Installation Comple

Page 44 - 8.5.5 Communication Error

9.0 SYSTEM SETTINGS Seed Hawk Manual Seed Hawk Air Drill Monitor II Page 47 Pressing the MENU button on the Normal Operate Screen will access your S

Page 45 - 8.6 SPECIAL START-UP

1.0 INTRODUCTION Seed Hawk Manual Granular and Liquid Tanks Page 3 Congratulations on your choice of a Seed Hawk Tank to complement your farming op

Page 46 - Procedure:

Seed Hawk Manual Granular and Liquid Tanks Page 48 9.1.2 Replace a Sensor Replace a Sensor allows you to replace a bad sensor without installing

Page 47

Seed Hawk Manual Granular and Liquid Tanks Page 49 9.3 SPEED SETTINGS 9.3.1 Pulses Per Rev Pulses per Rev (revolution) are the number of pulses

Page 48

Seed Hawk Manual Granular and Liquid Tanks Page 50 2. Highlight Continue Calibrations and Press SELECT.  3. The display will

Page 49 - 9.0 SYSTEM SETTINGS

Seed Hawk Manual Granular and Liquid Tanks Page 51 9.4 FAN SETTINGS Select which Fan you would like to view or make changes to. 9.4.1 Pulses Pe

Page 50

Seed Hawk Manual Granular and Liquid Tanks Page 52 9.6 METER SETTINGS 9.6.1 Meter Selection Select which Meter you would like to view or make c

Page 51 - 9.3.3 Speed Calibration

Seed Hawk Manual Granular and Liquid Tanks Page 53 9.6.3 Low Alarm Point This is the minimum meter RPM the monitor will recognize. If the meter

Page 52

Seed Hawk Manual Granular and Liquid Tanks Page 54 9.6.5 Meter Calibration & Procedures NOTE: For convenient calibration, your monitor is

Page 53

Seed Hawk Manual Granular and Liquid Tanks Page 55 Procedure: 1. Having Selected Meter (1, 2 or 3) Calibration, “Target 10.0lb/ac” is highlight

Page 54 - 9.6.2 Pulses Per Rev

Seed Hawk Manual Granular and Liquid Tanks Page 56 To begin, sufficient seed must be placed in the hopper above the meter to be calibrated to ens

Page 55 - 9.6.4 Weight / Rev

Seed Hawk Manual Granular and Liquid Tanks Page 57 6. The screen now displays the number of revolutions counted during the calibration. “Weight

Page 56 - 36 – 18 gear ratio

Seed Hawk Manual Granular and Liquid Tanks Page 4 1.1 DESCRIPTION OF THE MACHINE The Seed Hawk Inc. tank is a single axle tank which is designed

Page 57 - Procedure:

Seed Hawk Manual Granular and Liquid Tanks Page 58 9.7 FLOW SETTINGS Not applicable. 9.8 GLOBAL SETTINGS 9.8.1 Volume/Pitch Volume/P

Page 58

10.0 SCHEMATICS Seed Hawk Manual Granular and Liquid Tanks Page 59 10.1 TBH, TBT OR ON-BOARD HYDRAULICS (2010)

Page 59

Seed Hawk Manual Granular and Liquid Tanks Page 60 10.2 COMMON TANK WIRING HARNESS

Page 60

Seed Hawk Manual Granular and Liquid Tanks Page 61 10.3 AIR DRILL MONITOR II

Page 61 - 10.0 SCHEMATICS

11.0 WARRANTY Seed Hawk Manual Granular and Liquid Tanks Page 62 SEED HAWK INC. LIMITED WARRANTY STATEMENT Seed Hawk’s frame is warranted for fiv

Page 62

Seed Hawk Manual Granular and Liquid Tanks Page 63 Except as set forth above, Seed Hawk Inc. shall have no obligation or liability of any kind o

Page 63

12.0 NOTES Seed Hawk Manual Granular and Liquid Tanks Page 64 ______________________________________________________________________________________

Page 64 - 11.0 WARRANTY

Seed Hawk Manual Granular and Liquid Tanks Page 65 _______________________________________________________________________________________________

Page 65

Seed Hawk Manual Granular and Liquid Tanks Page 66 _______________________________________________________________________________________________

Page 66 - 12.0 NOTES

Seed Hawk Manual Granular and Liquid Tanks Page 67 _______________________________________________________________________________________________

Page 67

Seed Hawk Manual Granular and Liquid Tanks Page 5 1.3 MACHINE SERIAL NUMBER The serial number plate, FIG. 2, is located on the cradle near t

Page 68

Seed Hawk Manual Granular and Liquid Tanks Page 68 _______________________________________________________________________________________________

Page 69

Seed Hawk Manual Granular and Liquid Tanks Page 69 _______________________________________________________________________________________________

Page 70

13.0 INDEX Seed Hawk Manual Granular and Liquid Tanks Page 70 A M Agitate liquid fertilizer 31-32 Machine Serial Number 5Air and Product Fl

Page 71

2.0 SAFETY Seed Hawk Manual Granular and Liquid Tanks Page 6 WARNINGWARNINGCAUTIONCAUTION2.1 SAFETY ALERT SYMBOL The Safety Alert Symbol is intende

Page 72 - 13.0 INDEX

Seed Hawk Manual Granular and Liquid Tanks Page 7 2.2 OPERATOR RESPONSIBILITY Remember, YOU, the operator, are responsible for the safe operation

Commentaires sur ces manuels

Pas de commentaire