2010 Manual Retail Price $40.00 CDN/US Version 2.1
Seed Hawk Manual Granular and Liquid Tanks Page 8 2.3 GENERAL SAFETY PRACTICES Read and understand the contents of this Operator’s Manual prio
Seed Hawk Manual Granular and Liquid Tanks Page 9 2.4 MAINTENANCE SAFETY Read and understand all information provided in this Operator’s Manua
Seed Hawk Manual Granular and Liquid Tanks Page 10 2.5 HYDRAULIC SAFETY Ensure that all hydraulic system components are kept clean and in prop
Seed Hawk Manual Granular and Liquid Tanks Page 11 2.6 TRANSPORT SAFETY Ensure that drill or tank is attached to tractor properly. Ensure
Seed Hawk Manual Granular and Liquid Tanks Page 12 2.9 SAFETY SIGNS Location of Safety Sign on Implement FIG. 3
Seed Hawk Manual Granular and Liquid Tanks Page 13 2.9.1 Applied Safety Signs CAUTION! Read Operator’s Manual before operating machine. Read
Seed Hawk Manual Granular and Liquid Tanks Page 14 DANGER! ENTANGLEMENT HAZARD. Keep hands, feet, and clothing awa
Seed Hawk Manual Granular and Liquid Tanks Page 15 Safety Signs on Replacement Parts Ensure that parts or components that are replaced on the imp
3.0 SPECIFICATIONS Seed Hawk Manual Granular and Liquid Tanks Page 16 3.1 HARDWARE TORQUE 3.1.1 SAE Bolt Diameter Bol
Seed Hawk Manual Granular and Liquid Tanks Page 17 3.2 TIRE PRESSURE Use the following chart to check and adjust, if necessary, tire pressure.
3.0 OPERATION Seed Hawk Manual Granular and Liquid Tanks Page 18 4.1 FILL AUGER - 10 inch FIG 1 DANGER! ELECTROCUTION HAZARD. Use extreme caution
Seed Hawk Manual Granular and Liquid Tanks Page 19 4.1.1 Positioning the Auger NOTE: Ensure that the area in the vicinity of auger operation is f
Seed Hawk Manual Granular and Liquid Tanks Page 20 1. Ensure that all screens and shrouds are in place and that cleanout gate on each meter, FIG.
Seed Hawk Manual Granular and Liquid Tanks Page 21 4.1.4 Auger Transport Position IMPORTANT: Fill auger should always be secured for transport
Seed Hawk Manual Granular and Liquid Tanks Page 22 4.2 FAN(S) (OPTIONAL) (3/4” NON COLOR CODED) Connect the pair of 3/4” hydraulic lines to supp
Seed Hawk Manual Granular and Liquid Tanks Page 23 4.4 METERING ROLLER The metering roller provided in each compartment is designed to accommodat
Seed Hawk Manual Granular and Liquid Tanks Page 24 4.5 SEEDHAWK PRESSURIZED METERING SYSTEM FAN(S) Some models are configures
Seed Hawk Manual Granular and Liquid Tanks Page 25 4.6 CHECKING AIR AND PRODUCT FLOW The test procedure outlined below serves as a guideline for
Seed Hawk Manual Granular and Liquid Tanks Page 26 4.7 GROUND DRIVE METERING The ground drive metering system is engaged by activating an electr
5.0 LIQUID SYSTEM OPERATION Seed Hawk Manual Granular and Liquid Tanks Page 27 5.1 SEED HAWK LIQUID FERTILIZER SYSTEM FIG. 39. 1 Tank 2 Fill cap
Table of Contents 1.0 Introduction 3-5 1.1 Description of the Machine 4 1.2 Illustration of the Machine 4 1.3 Serial Number
Seed Hawk Manual Granular and Liquid Tanks Page 28 5.2 SYSTEM FLOW DESCRIPTION The metering pump, ground driven by the metering wheel, draws liqu
Seed Hawk Manual Granular and Liquid Tanks Page 29 5.3 FILLING THE LIQUID FERTILIZER TANK To fill the liquid fertilizer tank: 1. Remove fill ca
Seed Hawk Manual Granular and Liquid Tanks Page 30 5.5 CHECKING FERTILIZER RUNS Perform the following test to ensure that each fertilizer run is
Seed Hawk Manual Granular and Liquid Tanks Page 31 5.7 AGITATE LIQUID FERTILIZER It is recommended that the contents in the liquid fertilizer tan
Seed Hawk Manual Granular and Liquid Tanks Page 32 A liquid fill pump is an option when the liquid onboard tank is ordered. Usually located at t
Seed Hawk Manual Granular and Liquid Tanks Page 33 FIG.18 5.8 LIQUID FERTILIZER APPLICATION RATES JOHN BLUE PUMP Perform the following steps to
Seed Hawk Manual Granular and Liquid Tanks Page 34 5.8.1 Pump Settings 30.5L32 Rear Axle 3
Seed Hawk Manual Granular and Liquid Tanks Page 35 5.9 LIQUID PUMP GEAR RATIOS Gearing for Pumps Driven from the Rear Axle 30.5L32 Axle LM-4450
Seed Hawk Manual Granular and Liquid Tanks Page 36 Variable rate liquid chart. NOTE: Above charts are f
7.0 INTRODUCTION Seed Hawk Manual Seed Hawk Air Drill Monitor II Page 37 The SEED HAWK Air Drill Monitor is capable of monitoring and displaying:
6.0 Maintenance 36 6.1 Maintenance Schedule 36 7.0 Air Drill Monitor Introduction 37 8.0 Operation 38-46 8.1 Normal Startu
8.0 OPERATION Seed Hawk Manual Seed Hawk Air Drill Monitor II Page 38 8.1 NORMAL STARTUP Once all sensors have been installed and power has been pr
Seed Hawk Manual Granular and Liquid Tanks Page 39 8.3 CHANGING DISPLAYED FUNCTIONS The display of the monitor can be changed to show any of the
Seed Hawk Manual Granular and Liquid Tanks Page 40 In this example the top display is changed from reading Field Area to Fan RPM. Having pressed t
Seed Hawk Manual Granular and Liquid Tanks Page 41 8.5 ALARMS The alarm display will become active when any conditions fall below or rise above t
Seed Hawk Manual Granular and Liquid Tanks Page 42 8.5.3 Low and High Fan Speed Alarm A Low or High Fan Speed alarm occurs when fan RPM’s exceed
Seed Hawk Manual Granular and Liquid Tanks Page 43 8.6 SPECIAL START-UP A special start-up screen will appear when the monitor is turned on in
Seed Hawk Manual Granular and Liquid Tanks Page 44 8.6.1 Learn New System The Learn New System mode is a onetime process that identifies each se
Seed Hawk Manual Granular and Liquid Tanks Page 45 5. Install New System- Plug your sensors in as the monitor asks for them. For sensors that are
Seed Hawk Manual Granular and Liquid Tanks Page 46 6. When all sensors have been installed or skipped the monitor will display Installation Comple
9.0 SYSTEM SETTINGS Seed Hawk Manual Seed Hawk Air Drill Monitor II Page 47 Pressing the MENU button on the Normal Operate Screen will access your S
1.0 INTRODUCTION Seed Hawk Manual Granular and Liquid Tanks Page 3 Congratulations on your choice of a Seed Hawk Tank to complement your farming op
Seed Hawk Manual Granular and Liquid Tanks Page 48 9.1.2 Replace a Sensor Replace a Sensor allows you to replace a bad sensor without installing
Seed Hawk Manual Granular and Liquid Tanks Page 49 9.3 SPEED SETTINGS 9.3.1 Pulses Per Rev Pulses per Rev (revolution) are the number of pulses
Seed Hawk Manual Granular and Liquid Tanks Page 50 2. Highlight Continue Calibrations and Press SELECT. 3. The display will
Seed Hawk Manual Granular and Liquid Tanks Page 51 9.4 FAN SETTINGS Select which Fan you would like to view or make changes to. 9.4.1 Pulses Pe
Seed Hawk Manual Granular and Liquid Tanks Page 52 9.6 METER SETTINGS 9.6.1 Meter Selection Select which Meter you would like to view or make c
Seed Hawk Manual Granular and Liquid Tanks Page 53 9.6.3 Low Alarm Point This is the minimum meter RPM the monitor will recognize. If the meter
Seed Hawk Manual Granular and Liquid Tanks Page 54 9.6.5 Meter Calibration & Procedures NOTE: For convenient calibration, your monitor is
Seed Hawk Manual Granular and Liquid Tanks Page 55 Procedure: 1. Having Selected Meter (1, 2 or 3) Calibration, “Target 10.0lb/ac” is highlight
Seed Hawk Manual Granular and Liquid Tanks Page 56 To begin, sufficient seed must be placed in the hopper above the meter to be calibrated to ens
Seed Hawk Manual Granular and Liquid Tanks Page 57 6. The screen now displays the number of revolutions counted during the calibration. “Weight
Seed Hawk Manual Granular and Liquid Tanks Page 4 1.1 DESCRIPTION OF THE MACHINE The Seed Hawk Inc. tank is a single axle tank which is designed
Seed Hawk Manual Granular and Liquid Tanks Page 58 9.7 FLOW SETTINGS Not applicable. 9.8 GLOBAL SETTINGS 9.8.1 Volume/Pitch Volume/P
10.0 SCHEMATICS Seed Hawk Manual Granular and Liquid Tanks Page 59 10.1 TBH, TBT OR ON-BOARD HYDRAULICS (2010)
Seed Hawk Manual Granular and Liquid Tanks Page 60 10.2 COMMON TANK WIRING HARNESS
Seed Hawk Manual Granular and Liquid Tanks Page 61 10.3 AIR DRILL MONITOR II
11.0 WARRANTY Seed Hawk Manual Granular and Liquid Tanks Page 62 SEED HAWK INC. LIMITED WARRANTY STATEMENT Seed Hawk’s frame is warranted for fiv
Seed Hawk Manual Granular and Liquid Tanks Page 63 Except as set forth above, Seed Hawk Inc. shall have no obligation or liability of any kind o
12.0 NOTES Seed Hawk Manual Granular and Liquid Tanks Page 64 ______________________________________________________________________________________
Seed Hawk Manual Granular and Liquid Tanks Page 65 _______________________________________________________________________________________________
Seed Hawk Manual Granular and Liquid Tanks Page 66 _______________________________________________________________________________________________
Seed Hawk Manual Granular and Liquid Tanks Page 67 _______________________________________________________________________________________________
Seed Hawk Manual Granular and Liquid Tanks Page 5 1.3 MACHINE SERIAL NUMBER The serial number plate, FIG. 2, is located on the cradle near t
Seed Hawk Manual Granular and Liquid Tanks Page 68 _______________________________________________________________________________________________
Seed Hawk Manual Granular and Liquid Tanks Page 69 _______________________________________________________________________________________________
13.0 INDEX Seed Hawk Manual Granular and Liquid Tanks Page 70 A M Agitate liquid fertilizer 31-32 Machine Serial Number 5Air and Product Fl
2.0 SAFETY Seed Hawk Manual Granular and Liquid Tanks Page 6 WARNINGWARNINGCAUTIONCAUTION2.1 SAFETY ALERT SYMBOL The Safety Alert Symbol is intende
Seed Hawk Manual Granular and Liquid Tanks Page 7 2.2 OPERATOR RESPONSIBILITY Remember, YOU, the operator, are responsible for the safe operation
Commentaires sur ces manuels