Vue de la page 26
OPERATION
CHECKING AIR AND
PRODUCT FLOW
The test procedure outlined
below serves as a guideline for
ensuring proper fan speed for
effective delivery of product:
1. Remove hose(s) from an
outside opener and
temporarily attach to the
frame of the seeder with
the hose looping no more
than 12 in (300 mm)
below the frame.
2. Begin seeding at normal
field speed and observe
distance product
discharges from hose(s)
attached to the frame.
NOTE: All
product should
discharge at a
distance within a
range of 12 - 24
in (300 - 600
mm).
1
3. Adjust fan speed, if
necessary, to ensure
optimum air flow for
product discharge.